How does the BV300DP wire to the DSC PC1832 ?
The wiring consists of 4 colors, I'll use red,black,yellow and green for example Connect the BV300DP 12v+ to the 1832s AUX+ terminal using the red wire Connect the black wire from the BV300DPs GND terminal to the 1832 AUX- terminal The yellow and green wires will connect from the BV300DP N/C an ...
PC1616/PC1832/PC1864 - Example of changing a zone type.
To change the zone types, you enter programming with * 8 5555 The section related to zone types for zones 1-16 is section 001, so you'd press 001 The very next 2 digit entry, fills in the zone type for zone 1 and moves you to the zone 2 , entering a 2 digit zone type for zone 2 will automatical ...
PC5010 - Programming example
( The following programming represents the program for a system that did not use the end of line resistors on the hardwired zones. ) If you did use the resistors, enter 013 6 # instead of what is found below. This example has a zone list as follows; Zone 1= Front delay door (there is a ...
PC1555MX - Programming example
( The following programming represents the program for a system that did not use the end of line resistors on the hardwired zones. ) If you did use the resistors, enter 013 6 # instead of what is found below. This example has a zone list as follows; Zone 1= Front delay door (there is a ...
DSC Power Series Keypads - My keypad will not respond when I press any key but appears to have power, what can I do?
The following steps should correct the situation. Press and hold the # key for 3 seconds then release. Now press and hold the 1 key for 3 seconds and the keypad should respond. Press * 8 (Installers code, commonly 5555) 000 0 11 # # # The keypad should now respond to all keys when pressed.
PC1832 - How do I change my master code?
Enter *5, Enter 4 digit master code, Enter 40, Enter new 4 digit master code, Enter #