Knowledgebase

Choose a Product

There are no sub categories

Product » Vistarss button

There were 13 articles found in this Section:

  1. questionVista15P 20P - What is the default Installers code?
    A. The Installers code has been set to 4112 at the manufacturer.
  2. questionVista15P 20P - Why does the keypad display "fire zone trouble" upon power up?
    A. The control has already been programmed by the manufacturer so zone 1 can be used for a 2 wire smoke detector.If the 2000ohm resistor with the color bands Red Black Red Gold is not wired to zone 1 yet,or has been wired for a door,this message will appear.The zone type can be changed through ...
  3. questionVista15P 20P - Why do I have all of these resistors? Which ones do I use
    A. The resistors are used 1 per zone.The correct resistor for use on zone wiring have color bands Red Black Red gold.The manufacturer provides "zone doubling" resistors not typically used, keep these spare resistors in the control cabinet for possible future use.
  4. questionVista15P 20P - Why don't I see any info displayed on my keypad?
    - To address the keypad, unplug the systems ac transformer and disconnect the back up battery. - Wait 15 seconds then reconnect the battery and plug in the ac transformer. - Press and hold the 1 and 3 keys down for 3 seconds or until the keypad beeps then press 16 * * * - This sets the keypad ad ...
  5. questionVista15P 20P - How do I access system programming?
    A. Pressing 4112800 will allow access to programming
  6. questionVista15P 20P - What is the default Master Code?
    A. The default Master code is 1234
  7. questionVista15P 20P - How can I change the Master Code?
    A. Enter (Current Master code) 802 (new 4 digit master code) (new 4 digit master code again)
  8. questionVista15P 20P - Will my system call my cell phone?
    A. No, the systems dialer is designed for reproting to a monitoring centers electronic receiver. You may add a voice dialer and appropriate relay to receive your pre-recorded messages on your cell phone during an alarm condition.
  9. questionVista15P 20P - What does the message" Check 100" mean?
    A. The message "check 100 " will appear when the systems wireless receiver is disconnected or when a hardwired zone has been programmed with an incorrect "Input Type" such as 03 RF during setup.
  10. questionVista15P 20P - Can more than 1 siren be connected to this
    A. Yes, as long as the total amount of current draw does not exceed 1400milliamps.Typically 1 inside and 1 outside siren can be accomodated without an extra power supply and relay.
  11. questionVista15P 20P - Why do all the zones appear as "fault"?
    A. Each zone that appears may not be wired or may not have the resistor wired properly.
  12. questionVista15P 20P - What does the message "E8" mean?
    A. The message E8 indicates that there are more wireless devices programmed into the system than the wireless receiver will accomodate.
  13. questionVista15P 20P - Why can't I access programming using 4112800?
    A. The Installers code may have been changed from 4112 to an unknown code or the *98 command was used to exit programming mode during the last programming session. * 99 should always be used to exit the installers programming mode. To regain access to the programming mode, unplug the ac power tr ...